Catalog FORMAT plus - EDE 2015 - 2017
945
Voltage and continuity tester
Voltage and continuity tester
Design: Tested and approved in line with EN/IEC 61243-3 (DIN VDE 0682 Part 401), bipolar. Casing made of impact-resistant and unbreakable plastic, with rubber handle surface, two test handles and flexible connection cable. Direct display without push-button (high resistance), load connection via push buttons (low resistance), vibration alarm. Application: For professional testing of DC and AC voltages and for phase and polarity tests with deliberate triggering of the earth leakage circuit breaker.
IP 65 CAT IV
5560 0020
DUSPOL ® analogue For the professional testing of voltage, phasing and polarity, as well as the rotary field direction. DUSPOL ® expert For professional checking voltage, continuity, phase and polarity as well as the phase sequence. No-contact phase tester/cable break detector (yellow LED flashing). Supplied with batteries, voltage display from 50 V even when the batteries are empty. DUSPOL ® digital For professional checking of voltage, continuity, diode, phase and polarity, phase sequence as well as measuring resistance and frequency. No-contact voltage tester/cable break detector (yellow LED flashing). Measuring point and display lighting. Supplied with batteries, voltage display from 50 V even when the batteries are empty.
5560 0010
5560 0020
5560 0030
5560 0010
5560 0030
0020
0010
0030
Order No.
Model
DUSPOL ® analogue
DUSPOL ® expert
DUSPOL ® digital
5560
51.20
60.50
92.10
Display
Plunger coil/LED
LED
LED/LCD 1–1200 V 1–1000 V
DC voltage AC voltage Resistance
12–1000 V 12–1000 V
12–1000 V 12–1000 V
– – –
–
0.1 kOhm-300 kOhm LED, yellow/buzzer
Continuity test
LED, yellow/buzzer
Frequency
–
1–1000 Hz LED, green
5 Hand Tools
Phase sequence test
LCD LCD LED
LED, green
Phase test Polarity test
LED, red
LED, red
LED
LED
Load connection Vibration alarm
yes yes
yes yes yes
yes yes yes
Measuring point illumination
–
Measurement category Measuring procedure
CAT IV 600 V, CAT III 1000 V
CAT IV 600 V, CAT III 1000 V
CAT IV 600 V, CAT III 1000 V
–
–
TRUE RMS
Protection type
IP 65
IP 65
IP 65
Batteries
–
2 x micro AAA/LR03
2 x micro AAA/LR03
(514)
m
Protective case for voltage tester DUSPOL ®
Design: Made of durable nylon fabric with hook-and-loop fastener and belt loop.
5560
Dimensions mm
Order No. 1000
330 x 100 x 60
16.90 (514)
m
Continuity and line tester DUTEST ® pro
Design: Housing made of impact resistant and unbreakable plastic, with two test handles, flexible test leads and a magnet holder. With visual and audible signal, external voltage and battery voltage display. Precise high power LED flashlight, buzzer volume (3-stage/OFF) and luminosity (4 levels) adjustable. Integrated self-test for LED, LED flashlight and buzzer. Supplied without batteries. Application: For high and low resistance continuity testing of electrical wiring, facilities, equipment and components as well as for polarity testing and contactless phase testing phase. Order No. 0010 Continuity test 0–100 Ohm/1 kOhm/10 kOhm (LED/buzzer) 5575 29.90 Polarity test LED External voltage display 6 V–400 V (LED/buzzer) Measurement category CAT III 300 V Protection type IP 30 Batteries 3 x Mignon AA/LR6 (514)
CAT III
5/75
Articles marked ◊ are not held in stock, procurement is effected at short notice.
Not all items are available in every country.