html-Catalog FORMAT plus - EDE 2015 - 2017

868

Measuring and testing equipment

m

Hardness tester Shore-Duometer

Design: With drag indicator, max. mode captures the peak value, point mode shows the stable measured value. Supplied in a wooden box. Application: Measuring the Shore penetration depth: plastics, resin, Formica, epoxy, acrylic etc. Recommended especially for internal comparison measurements, where standard calibration, e.g. according to DIN 53505 is not possible.

4941

Measurement range

Order No. 0100

Reading

Hardness

100 HD

130.00

1.0 HD

Shore D

(498)

m

Lever test stand for Shore-Duometer

Design: For reproducible hardness testing with base plate of glass. High measurement accuracy due to increased hardness of the base plate. Mechanical design allows precise measurement movements. Levelling device for precise levelling of the base plate. Levelling test bench for inhomogeneous test objects. Application: Suitable for Shore hardness testing of plastics, leather, etc. The SAUTER HB hardness tester is mounted in a hanging position. The test object is placed on the round testing table right under the probe tip. By depressing the lever, the probe tip is pressed in a defined manner into the test object. Note: The accuracy of the measurement result with this test is about 25 % higher than for a hand measurement. Supplied without Shore-Duometer.

4941

Stroke length mm

Order No. 0110

measuring face ∅ mm

15

260.00

75

Equipment

4 Measuring

(498)

m

Leeb hardness test device HMM

Design: Rebound module is jerked by a spring against the test object. The speed reduction is measured and converted into Leeb hardness values. Tests at any angle (360°) due to automatic compensation. Mini statistics function displays the measured value, average value, the diffe- rence between maximum and minimum value, date and time. Measuring value display: Rockwell (B & C), Vickers (HV), Brinell (HB), Shore (HSD), Leeb (HL), tensile strength (MPa). Automatic unit conversion, so that measurement result is automatically re-evaluated in all the cited hard- ness units. Function: Accuracy: 1 % at 800 HLD (± 6 HLD) thinnest measurable layer: 8 mm minimum radius of curvature of the test object (concave/convex): 50 mm Supplied: Impact device (type D), infrared printer, hardness reference block, AC adapter and 3 micro batteries AAA/LR03, in plastic case. Note: Replacement battery (Order No. 9041 0020, Ç 9/10).

4941

Measurement range yield strength

Order No. 1000

Readability (d) HL Internal data memory

375–2639

1270.00

1

9

(498)

m

Accessories for Leeb hardness test device

4941

Design

Order No. 1010

Application

Rebound sensor

415.00

Short sensor for narrow and flat measurement openings

1015 1020

Attachment ring

270.00 115.00

For secure positioning

Impact body

4941 1010

(498)

4941 1015

4941 1020

4/140

All stocked articles available within 24 hours by UPS Express.

All prices excluding VAT per piece (if not stated otherwise).

Made with