Test and measuring devices
Digital multimeter
Design: Casing made of impact-resistant plastic. Application: For the measuring of DC and AC voltages as well as current and resistance, frequency and capacity, continuity and diode testing. MM 1 Supplied with protective rubber case, compact protective bag, dual-insulated safety measurement lines and batteries. MM 2 Supplied with protective rubber case, compact protective bag, dual-insulated safety measurement lines and batteries. MM 3 Supplied with protective rubber case, compact protective bag, dual-insulated safety measurement lines and batteries. MM 4 Supplied with AC current pliers attachment, measuring probes, compact protective bag, dual-insulated safety measurement lines and batteries. MM 7-1 Automatic voltage function for automatic identification of DC/AC voltage, low input impedance (LoZ) for the suppression of capacitive/inductive interspersed voltages. Supplied with wire temperature sensor with adapter, rubber protective case, compact protective bag, dual-insulated safety measurement lines as well as batteries. 5587 0005 5587 0050 5587 0100 5587 0251 5584 0005
IP 30
5 Hand Tools
5584 0005
5587 0005
5587 0050
5587 0100
5587 0251
CAT III
CAT III
CAT III
CAT III
CAT IV
0005 MM 1 76.00
0005 MM 2
0050 MM 3
0100 MM 4
0251
Order No.
Model
MM 7-1
5584 5587 DC voltage AC voltage
–
–
–
–
–
90.30
114.00
130.80
202.30
0.1 mV–600 V 1 mV–600 V 0.1 µA–3.2 mA
0.1 mV–1000 V 0.1 mV–750 V
0.1 mV–600 V 0.1 mV–600 V 0.1 µA–20 A 0.1 µA–20 A
1 mV–600 V 1 mV–600 V
10 µV–1000 V 10 µV–1000 V
Direct current
0.1 µA–20 A 0.1 µA–20 A
–
10 µA–10 A 10 µA–10 A
Alternating current
–
0.1 A–300 A
Resistance
0.1 Ohm–32 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–42 MOhm 0.1 Ohm–40 MOhm
Continuity/diodes
yes/yes
yes/yes
yes/yes
yes/yes
yes/yes
Frequency
– – – –
– – – –
1 Hz–200 kHz 1 pF–200 µF
– – –
0.01 Hz–100 kHz
Capacity
1 nF–10 mF
Temperature Pliers opening
– –
–40 °C to +400 °C
30mm
–
Measurement category Measuring procedure
CAT III 600 V
CAT III 600 V
CAT III 300 V
CAT III 300 V
CAT IV 600 V
RMS IP 30
RMS IP 30
RMS IP 30
RMS IP 30
TRUE RMS
Protection type
IP 30
Batteries
2 x micro AAA/LR03 1 x 6LR61 block battery 1 x 6LR61 block battery 2 x micro AAA/LR03 1 x 6LR61 block battery
Display
LCD
LCD
LCD
LCD
LCD
(514)
The measurement categories CAT I to CAT IV CAT I valid for measurements performed on circuits not directly connected to the network (e.g. specially protected devices) CAT Il Valid for measurements in building installation (e.g. distribution, wiring, sockets, switches) CAT III Valid for measurements in the building installation (e.g. distribution, wiring, sockets, switches) CAT IV Valid for measurements at the source of low-voltage installations (e.g. counters, main terminal, primary excess current protection devices).
Y 1 distribution Y 2 counter Y 3 outside trans- former station Y 4 underground cables
5/77
Articles marked ◊ are not held in stock, procurement is effected at short notice.
Not all items are available in every country.