Catalog FORMAT plus - EDE 2015 - 2017
Test and measuring devices 948
Digital current clamp multimeter
Design: Housing made of impact-resistant, unbreakable plastic, with automatic shutdown function. Application: For the safe current measurement at insulated cables, without having to remove or damage the insulation.
IP 30
5585 0101 5585 0102 5585 0200
CM 1-1 Supplied with compact protective bag and battery.
CM 1-2 Supplied with compact protective bag, battery and dual-insulated safety measurement lines. CM 2 Precise due to true RMS measurement procedure TRUE RMS. Tested and approved according to IEC/EN 61010-1 (DIN VDE 0411-1). Ideal for measuring small currents. Supplied with compact protective bag, double insulated safety measurement cables and batteries. CM 5-1 Automatic selection of correct measuring function, incorrect measurements as a result of choosing the wrong measuring range prevented, quick reaction times thanks to 5 samples per second. The voltage measurement takes place with low input impedance (LoZ) for the suppression of capacitive/inductive interspersed voltages. For continuity and diode testing. Supplied with compact protective bag, double insulated safety measurement cables and battery. CM 7 Ideal for measuring current up to 1000 A (alternating and direct current). Supplied with compact protective bag, dual-insulated safety measurement lines and batteries.
5585 0501
5585 0700
5585 0101
5585 0102
CAT III
CAT III
0101
0102
0200 CM 2
0501
0700 CM 7
Order No.
Model
CM 1-1 CM 1-2
CM 5-1 247.00
5585 DC voltage AC voltage
59.60
79.70
170.90
265.90
– 0.1 V–600 V 1 mV–600 V 0.7 V–1000 V 0.1 V–1000 V
– 0.1 V–600 V 0.1 mV– 600 V
1.3 V–750 V 0.1 V–750 V
Direct current
–
–
10 mA– 300 A
0.9 A–600 A 0.1 A–1000 A
Alternating current
10 mA– 400 A
0.1 A–400 A 100 mA– 300 A
0.9 A–600 A 0.1 A–1000 A
Resistance
–
0.1 Ohm– 20 MOhm
0.1 Ohm– 40 MOhm
1 Ohm– 10 kOhm
0.1 Ohm– 400 Ohm
5 Hand Tools
Continuity Frequency
– –
yes
yes
yes
yes
–
–
–
1 Hz–400 Hz
Measured data storage
HOLD, MAX HOLD HOLD, MAX HOLD HOLD, MAX/ MIN, PEAK, ZERO
Measuring procedure
RMS
RMS TRUE RMS TRUE RMS TRUE RMS
Pliers opening
30 mm 30 mm 25 mm 35 mm 53 mm CAT III 600 V CAT III 600 V CAT III 300 V CAT IV 600 V CAT IV 600 V
5585 0501
5585 0200
5585 0700
Measurement category
Protection type
IP 30
IP 30
IP 30
IP 30
IP 30
CAT IV
CAT III
CAT IV
Batteries
1 x 6LR61 block battery
2 x micro AAA/LR03
2 x micro AAA/LR03
1 x 6LR61 block battery
1 x 6LR61 block battery
Display
LCD
LCD
LCD
LCD
LCD
(514)
Current leakage meter
Design: Housing made of impact-resistant, unbreakable plastic, with automatic shutdown function. Automatic range selection, resolution of 1 uA at 6 mA measuring range. Precise due to true RMS measurement procedure TRUE RMS. Optimally shielded from foreign fields. Supplied with compact protective bag and batteries. Application: For locating current leakages and measuring leakage and residual currents in electrical installations (VDE 0100) and devices (VDE 0701/0702, DGUV Rule 3, Industrial Safety Ord.). Measurement during normal operation of the plant/unit, ideal for preventive maintenance and troubleshooting, reliable and easy to locate insulation faults. Switchable low-pass filter (50–60 Hz). Order No. 0900 Model CM 9 5585 393.00 Alternating current 1 µA–100 A Measured data storage HOLD, PEAK Measuring procedure TRUE RMS Pliers opening 40 mm Measurement category CAT III 300 V Protection type IP 30 Batteries 2 x micro AAA/LR03 Display LCD (514)
IP 30 CAT III
5/78
All stocked articles available within 24 hours by UPS Express.
All prices excluding VAT per piece (if not stated otherwise).
Made with FlippingBook