Catalog FORMAT plus - EDE 2015 - 2017

Test and measuring devices 948

Digital current clamp multimeter

Design: Housing made of impact-resistant, unbreakable plastic, with automatic shutdown function. Application: For the safe current measurement at insulated cables, without having to remove or damage the insulation.

IP 30

5585 0101 5585 0102 5585 0200

CM 1-1 Supplied with compact protective bag and battery.

CM 1-2 Supplied with compact protective bag, battery and dual-insulated safety measurement lines. CM 2 Precise due to true RMS measurement procedure TRUE RMS. Tested and approved according to IEC/EN 61010-1 (DIN VDE 0411-1). Ideal for measuring small currents. Supplied with compact protective bag, double insulated safety measurement cables and batteries. CM 5-1 Automatic selection of correct measuring function, incorrect measurements as a result of choosing the wrong measuring range prevented, quick reaction times thanks to 5 samples per second. The voltage measurement takes place with low input impedance (LoZ) for the suppression of capacitive/inductive interspersed voltages. For continuity and diode testing. Supplied with compact protective bag, double insulated safety measurement cables and battery. CM 7 Ideal for measuring current up to 1000 A (alternating and direct current). Supplied with compact protective bag, dual-insulated safety measurement lines and batteries.

5585 0501

5585 0700

5585 0101

5585 0102

CAT III

CAT III

0101

0102

0200 CM 2

0501

0700 CM 7

Order No.

Model

CM 1-1 CM 1-2

CM 5-1 247.00

5585 DC voltage AC voltage

59.60

79.70

170.90

265.90

– 0.1 V–600 V 1 mV–600 V 0.7 V–1000 V 0.1 V–1000 V

– 0.1 V–600 V 0.1 mV– 600 V

1.3 V–750 V 0.1 V–750 V

Direct current

10 mA– 300 A

0.9 A–600 A 0.1 A–1000 A

Alternating current

10 mA– 400 A

0.1 A–400 A 100 mA– 300 A

0.9 A–600 A 0.1 A–1000 A

Resistance

0.1 Ohm– 20 MOhm

0.1 Ohm– 40 MOhm

1 Ohm– 10 kOhm

0.1 Ohm– 400 Ohm

5 Hand Tools

Continuity Frequency

– –

yes

yes

yes

yes

1 Hz–400 Hz

Measured data storage

HOLD, MAX HOLD HOLD, MAX HOLD HOLD, MAX/ MIN, PEAK, ZERO

Measuring procedure

RMS

RMS TRUE RMS TRUE RMS TRUE RMS

Pliers opening

30 mm 30 mm 25 mm 35 mm 53 mm CAT III 600 V CAT III 600 V CAT III 300 V CAT IV 600 V CAT IV 600 V

5585 0501

5585 0200

5585 0700

Measurement category

Protection type

IP 30

IP 30

IP 30

IP 30

IP 30

CAT IV

CAT III

CAT IV

Batteries

1 x 6LR61 block battery

2 x micro AAA/LR03

2 x micro AAA/LR03

1 x 6LR61 block battery

1 x 6LR61 block battery

Display

LCD

LCD

LCD

LCD

LCD

(514)

Current leakage meter

Design: Housing made of impact-resistant, unbreakable plastic, with automatic shutdown function. Automatic range selection, resolution of 1 uA at 6 mA measuring range. Precise due to true RMS measurement procedure TRUE RMS. Optimally shielded from foreign fields. Supplied with compact protective bag and batteries. Application: For locating current leakages and measuring leakage and residual currents in electrical installations (VDE 0100) and devices (VDE 0701/0702, DGUV Rule 3, Industrial Safety Ord.). Measurement during normal operation of the plant/unit, ideal for preventive maintenance and troubleshooting, reliable and easy to locate insulation faults. Switchable low-pass filter (50–60 Hz). Order No. 0900 Model CM 9 5585 393.00 Alternating current 1 µA–100 A Measured data storage HOLD, PEAK Measuring procedure TRUE RMS Pliers opening 40 mm Measurement category CAT III 300 V Protection type IP 30 Batteries 2 x micro AAA/LR03 Display LCD (514)

IP 30 CAT III

5/78

All stocked articles available within 24 hours by UPS Express.

All prices excluding VAT per piece (if not stated otherwise).