Laser Scan Micrometer Measuring Unit Series 544 LSM-500S High Accuracy Non-contact Measuring System – Measuring range starting from ø5 µm. – Provides ultra-high accuracy with a linearity of ±0,3 µm over the entire measuring range (5 µm up to 2 mm).

Specifications Linearity at 20°C *¹ Positional error *² Repeatability (±2 ơ ) Measuring region Laser wavelength

±0,3 µm ±0,4 µm ±0,03 µm 1 x 2 mm

650 nm, Visible

Scanning rate Scanning speed

3200 scans/s

76m/s

Applicable laser standards

IEC, FDA

– Ultra-high repeatability of ±0,03 µm. – High scanning rate of 3200 scans/s

Optional accessories No.

Description

Membrane sheet, LSM-9506 Wire guiding pulley, for LSM-500

02AGD110 02AGD200 02AGD220

Air Shield LSM-500S

957608 Air Cleaner for Air Shield 02AGN780A Extension Signal Cable 5m 02AGN780B Extension Signal Cable 10m 02AGN780C Extension Signal Cable 15m

LSM-500S

Metric

No. Resolution (selectable) 544-532 0,005-2 0,00001-0,01 mm Range [mm]

Series 544 LSM-501S

Specifications Linearity at 20°C *¹

Entire range : ± 0,5 µm Narrow range : ±(0,3+0,1 Δ D) µm

High Accuracy Non-contact measuring system – Provides ultra-high accuracy with a linearity of ±0,5 µm over the entire measuring range (0,05 mm to 10 mm) and ±(0,3+0,1 Δ D) µm in the narrow range.

Positional error *² Repeatability (±2 ơ ) Measuring region Laser wavelength Scanning rate Scanning speed

±0,5 µm ±0,04 µm

2 x 10 mm (ø0,05-0,1 mm) 4 x 10 mm (ø0,1-10 mm)

– Ultra-High repeatability of ±0,04 µm. – High scanning rate of 3200 scans/s

650 nm, Visible

3200 scans/s

113 m/s IEC, FDA

Applicable laser standards

Optional accessories No.

Description

Calibration Gauge Set, Ø 0,1 - 10mm Wire guiding pulley, for LSM 501S

02AGD120 02AGD210 02AGD400 02AGD440 02AGD450 02AGD230

Workstage for LSM

Centre support LSM-501S/503S/902

LSM-501S

V-Block

Air Shield LSM-501S

957608 Air Cleaner for Air Shield 02AGC150A Relay Extension Cable 02AGN780A Extension Signal Cable 5m 02AGN780B Extension Signal Cable 10m 02AGN780C Extension Signal Cable 15m 02AGD440 and 02AGD450 : use with an adjustable workstage *¹ At the centre of the measuring region *² Potential measurement error due to variation in workpiece position within the measuring region Δ D = Difference in diameter between the mastergauge and workpiece

Metric

No. Resolution (selectable) 544-534 0,05-10 0,00001-0,01 mm Range [mm]

Refer to the LSM brochure